Built for the Nebius × NVIDIA Global AI Hackathon 2026, Physical AI track. Models: Nemotron on Nebius Token Factory. The ISS examples were recorded on Nemotron 3 Nano and Super, which leave Token Factory serverless on 9 Nov 2026; your own clips run on Nemotron 3.5 Lightning and Super VL in their place. Simulator: MuJoCo in your browser. Apache-2.0, source on GitHub.

All clips

ISS glovebox pipetting into sample cartridge

ISS: pipette into a sample cartridge (NASA, 10.8 s). Recorded on 27 October 2026 as run 4 of 4 recording runs of this clip, the first that passes on Earth and in orbit; labels and patches vary from run to run. Its 4 model calls cost US$0.0027 in all. The last version of its program passes on Earth and in orbit.

1

The clip

The only other input is the line its uploader would type. It names the task, and that matters: in our label measurements only a hint that names the task got the model to name the object being moved.

“aboard the ISS, in a glovebox, pipetting liquid into a sample cartridge”

The clip goes to the model as a small copy: 480 pixels wide, 4 frames a second, no sound.

2

What the model saw

Nemotron 3.5 Super VL

A crew member in a glovebox holds a small rectangular sample cartridge in the left hand and uses a pipette in the right hand to dispense liquid into its wells, repeating the pipetting action several times.

  • sample cartridgebox, 45 × 30 × 12 mm, manipulated
  • pipettebox, 240 × 25 × 25 mm, manipulated
  • black traybox, 180 × 120 × 15 mm, surface
  • glovebox work surfacebox, 600 × 500 × 10 mm, surface
  1. 0–1 sreach the sample cartridge
  2. 1–1 sgrasp the sample cartridge
  3. 1–2 smove the sample cartridge to the glovebox work surface
  4. 2–4 sinsert the pipette into the sample cartridge
  5. 4–5 sretract the pipette
  6. 5–6 sinsert the pipette into the sample cartridge
  7. 6–7 sretract the pipette
  8. 7–9 sinsert the pipette into the sample cartridge
  9. 9–10 sretract the pipette
  10. 10–10 srelease the sample cartridge

Fitted to the robot’s bench

The SO-101 rehearses one manipulation: the pipette goes into the sample cartridge, laid out within its reach and sized for its gripper. Everything the fit changed or left out:

  • the pipette: size [240, 25, 25] mm scaled to [25, 25, 40] mm for the robot's jaws and reach
  • the sample cartridge: size [45, 30, 12] mm scaled to [65, 65, 12] mm for the robot's jaws and reach
  • left out of the rehearsal: black tray, glovebox work surface
  • rehearsing a grasp and step s4 of 10
What the checks flagged in the label
  • object work_surface: size_mm [600, 500, 10] is outside 5 to 300 mm
3

What the robot asked

Nemotron 3 Nano

Nano writes the robot’s program and turns every value it would otherwise have to guess into a question for the person who did the task. The answers below were given when recording, standing in for the crew member; each round recompiles the program.

  1. How much wider than the pipette is the opening of the sample cartridge?the pocket's clearance was not visible

    10 mm

  2. When does putting the pipette in the sample cartridge count as done?the step has no success check

    the pipette ends up in the sample cartridge and stays there

  3. What is the pocket_clearance_mm of the cartridge wells?the spec step mentions a pocket fixture but no clearance value

    5 mm

  4. Compile notes for round 1
    • added an ask for objects[cartridge].pocket_clearance_mm: the rehearsal needs it
    • added an ask for steps[s2].success: the rehearsal needs it
Version of the program:
4

The program

The robot's program

  1. s1 · grasp pipette

    1. move to 62 mm above the pipette, from the top
    2. move to 12 mm above the pipette, from the top
    3. close the gripper to 25 mm on the pipette
    4. wait until both pads touch the pipette (up to 1 s)
    5. move to 41.9 mm above the pipette, from the top
  2. s2 · insert pipette into the sample cartridge

    1. move to 46 mm above the sample cartridge, from the top
    2. move to 27 mm above the sample cartridge, from the top
    3. move to 20 mm above the sample cartridge, from the top
    4. open the gripper
    5. wait until the pipette is still (up to 2 s)
    6. check that the pipette is inside the sample cartridge

Nano noted: No scale reference visible; object sizes and poses are estimated.

5

The rehearsal

MuJoCo in your browser, SO-101

When it was recorded, version 2 of the program: on Earth it passes; in orbit it passes. Here it runs again.

Loading the simulator…
6

How it improved

When it was recorded, each version below was rehearsed once per world, on its own spec. The scoreboard runs every version on the same twelve changes to the world, the ones Nemotron 3.5 Super VL chose for this task when the perturbation grid was recorded, each blind (the program is told the poses the spec has while the world is moved) and sensed (it is told where things really are), on Earth and in orbit: 24 rollouts per world per version, all on the last version’s spec, in your browser, with no model call. Before them runs a baseline, “retarget and replay”: a program written by fixed rules from the label’s steps as fitted to the bench, with no model and no answers (take the object, carry it over the target, lower it, let go; no waits, no checks), scored the same way.

  1. Baseline: retarget and replay

    A program written by fixed rules from the label's steps as fitted to the bench, with no model and no answers. Never recorded: it runs only here.

    no model call

  2. 0. First compile

    Earth: fails: move_to the pipette + (0, 0, 50) mm from top: out of reach by 8.1 mm
    Orbit: fails: move_to the pipette + (0, 0, 50) mm from top: out of reach by 8.4 mm

    Why: Nano's first program for the fitted spec, with 3 open questions

    US$0.0003 for this version
    US$0.0019 so far

  3. 1. After 3 answers

    Earth: fails: move_to the pipette + (0, 0, 50) mm from top: out of reach by 8.1 mm
    Orbit: fails: move_to the pipette + (0, 0, 50) mm from top: out of reach by 8.4 mm

    • the pocket clearance of the sample cartridge: 10 mm
    • when "insert the pipette" counts as done: the pipette ends up in the sample cartridge and stays there
    • how far off "insert the pipette" may land (clearance): 5 mm

    Why: answers to: How much wider than the the pipette is the opening of the sample the sample cartridge? When does putting the the pipette in the sample the sample cartridge count as done? What is the pocket_clearance_mm of the the sample cartridge wells?

    US$0.0003 for this version
    US$0.0022 so far

  4. 2. Notes patch 1

    Earth: passes
    Orbit: passes

    • the height of the move to the pipette (s1 op 4): 50 → 41.9 mm

    Why: The the pipette was out of reach by ~8.2 mm when trying to lift to z=50 mm, indicating the target height exceeds the arm's capability.

    US$0.0004 for this version
    US$0.0027 so far

From version 2 on, the Notes stage takes over: Super reads what the simulator measured in the previous version’s rehearsal and changes the numbers of the step that failed, and each patch is rehearsed again on Earth and in orbit. It thinks only once the cheap answer gets stuck. In the three runs before it, five patches did not fix it: the first still failed on Earth and in orbit, the next two in orbit. On small probe programs of two to four knobs, the same loop fixed 94% of the failures that could be fixed.

All model calls for this recording: 4 calls on Nebius Token Factory, 11,732 tokens, US$0.0027 at list prices, 6.7 s.